 |
 |
|
 |
What's New? |
|
>> more info
|
 |
Upcoming Events |
| |
No events scheduled
at this time.
|
 |
UL-325 |
| |
Everything you wanted to know about
UL-325.
>> more info |
 |
Office Tour! |
| |
See pictures of our office and showroom.
>> more info |
|
|
 |
| |
DTK-120HW
AC Hardwired Transient Voltage Surge Suppressor.
Features:
Installation Point:
Single Circuit
Connection Method:
Hardwire parallel connection
Continuous Current:
Unlimited (Parallel Installation)
Service Voltage:
110 / 125 VAC
Max Surge Current:
22,500 Amps
Max Energy Dissipation:
190 Joules
Suppressed Voltage Rating:
600V
Operating Temperature Range:
-40 degrees C. to +85 degrees C.
Operating Environment:
Outdoor use, out of direct weather (5% to 100% non-condensing)
|
|
DTK-240HW
120/240V Hardwire 2 W+G.
Features:
Installation Point:
Single Circuit
Connection Method:
Hardwire parallel connection
Continuous Current:
Unlimited (Parallel Installation)
Service Voltage:
120 / 240 Split Phase
Max Surge Current:
27,000 Amps
Max Energy Dissipation:
228 Joules
|
|
DTK-2LVLP-LV
2 Pair Terminal Strip for low voltage line protection.
Features:
Installation Point:
Wire entry to building
Connection Method:
Screw terminals, #22-#14 awg wire
Continuous Current:
Unlimited
Service Voltage:
30V
Max Surge Current:
2000A (per pair)
Max Energy Dissipation:
17 Joules (per pair)
Wiring Configuration:
2,4,6 and 8 wire Models Available
Typical Let Through Voltage:
42.0 - 52.0 (per pair)
|
|
DTK-4LVLP-LV
4 Pair Terminal Strip for low voltage line protection.
Features:
Installation Point:
Wire entry to building
Connection Method:
Screw terminals, 22-14 awg wire
Service Voltage:
30V
Max Energy Dissipation:
17 Joules
Typical Let Through Voltage:
42 - 52
|
|
DTK-4LVLP-CR
Surge protection for card readers and Keypads.
Features:
Installation Point:
Grounding point for card readers, keypads, gate c
Connection Method:
Screw terminals, 14-22 awg wire
Continuous Current:
3 Amps (power) 150 mAmps (L.E.D. & Data)
AC Protection Modes:
All wires protected
Service Voltage:
12VDC or 24 VDC (power) <5VDC (LED & Data)
Max Surge Current:
3,000 Amps
Max Energy Dissipation:
37 Joules
Operating Temperature Range:
-40C - +85C
Operating Environment:
Outdoor use, out of direct weather
|
|
DTK-2LVLP-SCP-RUV
2 Pair Terminal Strip w/Sneak Current Protection for low voltage line
protection.
Features:
Installation Point:
Wire entry to building
Connection Method:
Screw terminals, 22 - 14 awg wire
Continuous Current:
<150 mAmps
Max Surge Current:
9000A per pair
Max Energy Dissipation:
76 Joules per pair
Typical Let Through Voltage:
130VRMS
|
|
DTK-4LVTEP
Low voltage telephone entry system protector.
Features:
Installation Point:
Grounding point for telephone entry system
Connection Method:
Screw terminals, 14-22 awg wire
Continuous Current:
12V/24V Power - 16 Amps, Data/Telco Tip and Ring - 150 mAmps
Service Voltage:
12 VDC/24 VDC (Power), <5VDC (Data), 120V (Telco)
Max Surge Current:
2,000 Amps (12V/24V Power, 9,000 Amps (Telco), 1200 Watts (Data) (per
pair)
Max Energy Dissipation:
8 Joules (12V Power), 16 Joules (24V Power), 76 Joules (Telco) (per pair)
|
|
<< Back To Manufacturer List
|
|
|